Abstract
It is suggested that 2D finite element method models are used for square
pillar stability analysis. Equivalent width of strip pillar that is represented by FE
models is determined from tributary area method by introducing equivalence of
square and strip pillar loads in tributary area method analysis. With FE analysis it
is shown that pillar loads are close to expected, but tributary area method is limited
to pillars of small heights and with horizontal deposits. Proposed methodology
provides opportunity to model much complex conditions and sequencing of
excavation with respect of sequential stress redistribution.