• Српски
    • Српски (Serbia)
    • English
  • English 
    • Serbian (Cyrilic)
    • Serbian (Latin)
    • English
  • Login
View Item 
  •   PLATON
  • Пољопривредни факултет
  • Главна колекција / Main Collection
  • View Item
  •   PLATON
  • Пољопривредни факултет
  • Главна колекција / Main Collection
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

A novel kinetic cholinesterase-inhibition based method for quantification of biperiden in pharmaceutical preparations

Thumbnail
View/Open
0367-598X2000021D.pdf (437.0Kb)
Authors
Djurić, Vladan Đ., Violeta M., Nebojša D., Marija I., Bratislav Ć., Vesna S. J., V., Mitić, V., Deletić, N., Ilić, M., Ćirković, B., Stankov-Jovanović, V.
Metadata
Show full item record
Abstract
Biperiden, an antiparkinsonian anticholinergic drug, has been found to inhibit enzymatic hydrolysis of butyrylthiocholine iodide, which is catalyzed by serum cholinesterase. By measuring the difference in the basic and inhibitory hydrolysis reaction rates, in the presence of biperiden as an inhibitor, it is possible to develop a kinetic method for its determination. Both systems, enzyme-substrate-chromogen and enzyme-substrate-chromogen-inhibitor, were characterized by biochemical parameters (KM = 0.326 – 0.330 mmol dm-3 ; Vmax = 40 - - 99 μmol dm-3 min-1 ), while inhibition was defined as non-competitive with the constant of inhibition Ki = 6.142 μmol dm-3 . The reaction conditions have been optimized followed by determination of the calibration curve, the corresponding equation and the limits of detection and quantification yielding 3.84 and 12.80 nmol dm-3 , respectively. Using the calibration chart, it is possible to determine biperiden in different samples in the concentration range of 0.035–35.940 µmol dm-3 . Influence of a number of substances, found in the sample, on the reaction rate was also examined. The optimized method was applied for determination of biperiden in pharmaceutical preparations. Accuracy of the method was tested using the standard addition method. The proposed method has good sensitivity, selectivity, it is simple and fast, and above all easily accessible, and thus applicable in biochemical and pharmaceutical laboratories.
URI
https://platon.pr.ac.rs/handle/123456789/439
DOI
doi.org/10.2298/HEMIND200413021D
M category
M23
openAccess
M23
openAccess
Collections
  • Главна колекција / Main Collection

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

All of DSpaceInstitutionsBy Issue DateAuthorsTitlesSubjectsThis institutionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV