Show simple item record

dc.contributor.authorJevtić, Sonja
dc.contributor.authorStefanović, Anđela
dc.contributor.authorStanković, Dalibor
dc.contributor.authorPergal, Marija
dc.contributor.authorIvanović, Aleksandra
dc.contributor.authorJokić, Anja
dc.contributor.authorPetković, Branka
dc.date.accessioned2023-04-12T10:57:42Z
dc.date.available2023-04-12T10:57:42Z
dc.identifier.citationMinistry of Science and Technological Development of the Republic of Serbia, Project Number III45022en_US
dc.identifier.citationMinistry of Science and Technological Development of the Republic of Serbia, Project Number OI172030en_US
dc.identifier.citationMagbiovin project (FP7- ERAChairs-Pilot Call-2013, Grant agreement: 621375)en_US
dc.identifier.urihttps://platon.pr.ac.rs/handle/123456789/1197
dc.description.abstractBentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 μM, with a detection limit of 0.5 μM. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.en_US
dc.language.isoen_USen_US
dc.titleBoron-doped diamond electrode-a prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samplesen_US
dc.title.alternativeDiamond and Related Materialsen_US
dc.typeclanak-u-casopisuen_US
dc.description.versionpublishedVersionen_US
dc.identifier.doihttps://doi.org/10.1016/j.diamond.2017.12.009
dc.citation.volume81
dc.citation.spage133
dc.citation.epage137
dc.subject.keywordsBentazone determinationen_US
dc.subject.keywordsElectrochemical methoden_US
dc.subject.keywordsVoltammetryen_US
dc.subject.keywordsRiver water samplesen_US
dc.type.mCategoryM22en_US
dc.type.mCategoryclosedAccessen_US
dc.type.mCategoryM22en_US
dc.type.mCategoryclosedAccessen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record